Call : 08045802954 Call : 08045802954

SDVC20-L: 10A

SDVC20-L: 10A

Product Details:

  • Protection Level IP67
  • Frequency (MHz) 50-60 Hz Hertz (HZ)
  • Rated Voltage 85-440 V Volt (V)
  • Energy Consumption 1.5-3W Energy
  • Output Type Switching Signal
  • Dimension(L*W*H) 180*106*58(L*W*H, mm) Millimeter (mm)
  • Weight 960g (without accessory) Grams (g)
  • Supply Ability : 1 Pair Per Week
1 INR/Pair
X

Price And Quantity

  • 1 INR/Pair
  • 1 Pair

Product Specifications

  • 50-60 Hz Hertz (HZ)
  • Switching Signal
  • 85-440 V Volt (V)
  • 1.5-3W Energy
  • 960g (without accessory) Grams (g)
  • 180*106*58(L*W*H, mm) Millimeter (mm)
  • 1 year
  • IP67

Trade Information

  • Cash Advance (CA), Cash in Advance (CID), Cheque
  • 1 Pair Per Week
  • 1 Week
  • 3 % Extra
  • All India
  • ISO

Product Description

FEATURES :
Automatic Voltage Regulation: Eliminate feed speed variation caused by mains voltage fluctuation.
Soft Startup: In order to avoid sudden shock to the feed material and vibratory feeder, the controller can gently increase output voltage from 0 to the preset value when startup.
Preset Speeds: 4 preset feed speeds can be stored and output by external short-circuit signal. Remote ON/OFF Control: The controller has 2 groups of ON/OFF control pins. Switch sensor or PLC can be connected to them to turn on/off the controller.
Photoelectric ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn on/off the controller.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with logical relation setting of the ON/OFF Control to drive a solenoid, an electrical relay or other external devices.
Overheat Protection: If internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If output current exceeds its rated value by mis-operation, the controller will stop its output to protect the controller and vibratory feeder.
Short-Circuit Protection: If output of the controller is short-circuited, the fuse inside the controller will be blown to protect the controller and vibratory feeder from further damage.

TECHNICAL SPECIFICATION

      ITEM

Range

 

Unit

 

Description

Min

Max

Input voltage

85

440

V

AC RMS Value

Output voltage

0

440

V

Less than Input voltage

Output Current

0

10

A

 

 

Output Frequency

50/100

Hz

Mains Frequency is 50Hz

60/120

Hz

Mains Frequency is 60Hz

Output Power

0

2200

VA

 

Output Waveform

Tangent Sine

 

 

Voltage Adjustment Accuracy

1

V

 

On / OFF Delay

0

20

S

 

ON / OFF Delay Accuracy

0.1

S

 

Soft Startup Time

0

10

s

 

DC Control Output Voltage

22

26

v

DC output associated with ON / OFF Control

 

DC Control Output Current

0

200

 mA

Standby Power Consumption

1.5

3

w

 

Display Method

4

digit

LED Digital Tube

Control Method

1.5

v

Remots Speed Control voltage

Standard TTL Electric Level

v

Switching Signal

/

 

4 Buttons + LED Screen

Work Space Temperature

-10

60

C

Non-condensing

Work Space Humidity

10

85

%

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'Vibrator Controllers CUH' category



Back to top
SAI TECH CONTROLS All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.