Product Details:
- Frequency (MHz) 50-100 Hz Hertz (HZ)
- Rated Voltage 85-260 Volt (V)
- Energy Consumption 1.5-3W Energy
- Output Type Switching Signal
- Dimension(L*W*H) 111*76*48.5(L*W*H, mm) Millimeter (mm)
- Weight 285g (without accessory) Grams (g)
- Warranty 1 year
- Supply Ability : 1 Piece Per Week
- Click to view more
X
Price And Quantity
- 1 INR/Pair
- 1 Piece
Product Specifications
- 1.5-3W Energy
- 85-260 Volt (V)
- 285g (without accessory) Grams (g)
- Switching Signal
- 1 year
- 50-100 Hz Hertz (HZ)
- 111*76*48.5(L*W*H, mm) Millimeter (mm)
Trade Information
- Cheque, Cash Advance (CA)
- 1 Piece Per Week
- 1 Week
- 3 % Extra
- All India
- ISO
Product Description
FEATURES :Automatic Voltage Regulation : Eliminate feed speed variation caused by mains voltage fluctuation.
Soft Startup : In order to avoid sudden shock to the feed material and vibratory feeder, the controller can gently increase output voltage from 0 to the preset value when startup.
Preset Speeds : 4 preset feed speeds can be stored and output by external short-circuit signal.
Remote ON/OFF Control : The controller has 2 groups of ON/OF control pins. Switch sensor ot PLC can be Connected to them to turn on/off the controller.
Photoelectric ON/OFF Control : The CUH Intelligent Photoelectric Sensor can be conrected to turn on/off the controller.
Remote Speed Control : Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1·5V DC signal.
DC Control Output : The controller can output low voltage Dc power associated with logical relation setting of tne ON/OFF Control to drive a solenoid, an electrical relay or other exiernal devices.
Overheat Protection : If Internal temperature of the controller gets too high. the controller will stop its output to protect itself.
Overcurrent Protection : If output current exceeds its rated value by misoperation, the controller will stop its output to protect the controller and vibratory feeder.
Short-Circuit Protection : If output of the controller is short-circuited, the fuse inside the controller will be blown to protect the controller and vibratory feeder from further damage.
TECHNICAL SPECIFICATION
Item | Range | Unit | Description | |
Min | Max | |||
Input voltage | 85 | 260 | V | AC RMS Vaule |
Output voltage | 0 | 260 | V | Less than Input voltage |
Output Current | 0 | 5 | A | |
Output Frequency | 50/100 | HZ | Mains Frequency is 50Hz | |
60/120 | HZ | Mains Frequency is 60Hz | ||
Output Power | 0 | 1100 | VA | |
Output Waveform | Tangent Sine | | | |
Voltage adjustmen Accuracy | 1 | V | | |
On/OFF Delay Accuracy | 0 | 20 | s | |
ON/OFF Delay Accuracy | 0.1 | s | | |
Soft Startup Time | 0 | 10 | s | |
DC Control output Voltage | 11 | 13 | V | DC output associated with ON/OFF control |
DC Control output current | 0 | 200 | mA | |
Stand by Power Consumption | 1.5 | 3 | w | |
Display Method | 4 | Digit | LED Digital Tube | |
Control Method | 1-5 | V | Remote Speed Control Voltage | |
Standard TTL Electric Level | | Switching Signal | ||
/ | | 4 Buttons + LED screens | ||
Work Space | -10 | 60 | °C | Non-Condensing |
Work Space Humidity | 10 | 85 | % |