SDVC22-S: 5A

SDVC22-S: 5A

1 INR/Pair

Product Details:

  • Protection Level IP67
  • Frequency (MHz) 50-100 Hz Hertz (HZ)
  • Rated Voltage 85-260 V Volt (V)
  • Energy Consumption 1.5-3W Energy
  • Output Type Switching Signal
  • Dimension(L*W*H) 130*106*57.5(L*W*H, mm) Millimeter (mm)
  • Weight 500g(without accessory) Grams (g)
  • Supply Ability : 1 Pair Per Week
  • Click to view more
X

Price And Quantity

  • 1 Pair
  • 1 INR/Pair

Product Specifications

  • Switching Signal
  • 1.5-3W Energy
  • IP67
  • 50-100 Hz Hertz (HZ)
  • 130*106*57.5(L*W*H, mm) Millimeter (mm)
  • 500g(without accessory) Grams (g)
  • 85-260 V Volt (V)
  • 1 year

Trade Information

  • Cheque, Cash in Advance (CID), Cash Advance (CA)
  • 1 Pair Per Week
  • 1 Week
  • 3 % Extra
  • All India
  • ISO

Product Description

FEATURES :
Automatic Voltage Regulation: Eliminate feed speed variation caused by mains voltage fluctuation.
Soft Startup: in order to avoid sudden shock to the feed material end vibratory feeder. the controller can gently increase output voltage from 0 to the preset value when startup.
Preset Speeds : 4 preset feed speeds can be stored and output by external short-circuit signal.
Remote ON/OFF Control: Each stde of the conttoller has 2 groups of ON/OFF control pins. Switch sensor or PLC can be connected to them to turn on/off the controller.
Photoelectric ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to tum on/off the controller.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external polentiometer, a PLC. or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with logical relation setting of the ON/OFF Control to drive a solenoid.

an electrical relay or other external devices.
Overheat Protection: if internal temperature of the controller gets too high. the conttoller will stop its output to protect itself.
Over current Protection: If output current exceeds its rated value by misoperation.the controller will stop its output to protect the controller and vibratory feeder.
Short -Circuit Protection: If output of the controller is short-circuited, the fuse inside the controller will be blown to protect the controller and vibratory feeder from further damage.

 TECHNICAL SPECIFICATIONS

      ITEM

Range

 

Unit

 

Description

Min

Max

Input voltage

85

260

V

AC RMS Value

Output voltage

0

260

V

Less than Input voltage

Output Current

0

5

A

 

 

Output Frequency

50/100

Hz

Mains Frequency is 50Hz

60/120

Hz

Mains Frequency is 60Hz

OutPut Power

0

1100

VA

 

Output Waveform

Tangent Sine

 

 

Viltage Adjestment Accuracy 1 v  
ON/OFF delay 0 20 s  
ON/OFF Delay Accuracy 0.1 s  
Soft Startup Time 0 10 s  
DC Control output Voltage 22 26 V DC output associated with ON/OFF control
DC Control output current 0 200 mA
Stand by Power Consumption 1.5 3 w  
Display Method 8 Digit LED Digital Tube

 

 

 

Control Method

1-5 V

Remote Speed

Control Voltage

Standard TTL Electric Level   Switching Signal
/   8 Buttons + 2LED screens

Work Space
Temperature

-10

60

°C

 

Non-Condensing

Work Space Humidity

10

85

  %