Product Details:

  • Protection Level IP67
  • Frequency (MHz) 50-60 Hz Hertz (HZ)
  • Rated Voltage 85-440 V Volt (V)
  • Energy Consumption 1.5-3W Energy
  • Output Type Switching Signal
  • Dimension(L*W*H) 180*106*58(L*W*H, mm) Millimeter (mm)
  • Weight 960g (without accessory) Grams (g)
  • Supply Ability : 1 Pair Per Week
1 INR/Pair
X

Price And Quantity

  • 1 Pair
  • 1 INR/Pair

Product Specifications

  • 1.5-3W Energy
  • IP67
  • Switching Signal
  • 50-60 Hz Hertz (HZ)
  • 180*106*58(L*W*H, mm) Millimeter (mm)
  • 960g (without accessory) Grams (g)
  • 1 year
  • 85-440 V Volt (V)

Trade Information

  • Cheque, Cash in Advance (CID), Cash Advance (CA)
  • 1 Pair Per Week
  • 1 Week
  • 3 % Extra
  • All India
  • ISO

Product Description

FEATURES :
Automatic Voltage Regulation: Eliminate feed speed variation caused by mains voltage fluctuation.
Soft Startup: In order to avoid sudden shock to the feed material and vibratory feeder, the controller can gently increase output voltage from 0 to the preset value when startup.
Preset Speeds: 4 preset feed speeds can be stored and output by external short-circuit signal. Remote ON/OFF Control: The controller has 2 groups of ON/OFF control pins. Switch sensor or PLC can be connected to them to turn on/off the controller.
Photoelectric ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn on/off the controller.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with logical relation setting of the ON/OFF Control to drive a solenoid, an electrical relay or other external devices.
Overheat Protection: If internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If output current exceeds its rated value by mis-operation, the controller will stop its output to protect the controller and vibratory feeder.
Short-Circuit Protection: If output of the controller is short-circuited, the fuse inside the controller will be blown to protect the controller and vibratory feeder from further damage.

TECHNICAL SPECIFICATION

      ITEM

Range

 

Unit

 

Description

Min

Max

Input voltage

85

440

V

AC RMS Value

Output voltage

0

440

V

Less than Input voltage

Output Current

0

10

A

 

 

Output Frequency

50/100

Hz

Mains Frequency is 50Hz

60/120

Hz

Mains Frequency is 60Hz

Output Power

0

2200

VA

 

Output Waveform

Tangent Sine

 

 

Voltage Adjustment Accuracy

1

V

 

On / OFF Delay

0

20

S

 

ON / OFF Delay Accuracy

0.1

S

 

Soft Startup Time

0

10

s

 

DC Control Output Voltage

22

26

v

DC output associated with ON / OFF Control

 

DC Control Output Current

0

200

 mA

Standby Power Consumption

1.5

3

w

 

Display Method

4

digit

LED Digital Tube

Control Method

1.5

v

Remots Speed Control voltage

Standard TTL Electric Level

v

Switching Signal

/

 

4 Buttons + LED Screen

Work Space Temperature

-10

60

°C

Non-condensing

Work Space Humidity

10

85

%


SAI TECH CONTROLS