Pune, Maharashtra, India

Call us: +919822083726

trusted seller

SDVC20- S

SDVC20- S

Product Details:

  • Frequency (MHz) 50-100 Hz Hertz (HZ)
  • Rated Voltage 85-260 Volt (V)
  • Energy Consumption 1.5-3W Energy
  • Output Type Switching Signal
  • Dimension (L*W*H) 111*76*48.5(L*W*H, mm) Millimeter (mm)
  • Weight 285g (without accessory) Grams (g)
  • Warranty 1 year
1 INR/Pair
X

SDVC20- S Price And Quantity

  • 1 INR/Pair
  • 1 Piece

SDVC20- S Product Specifications

  • 1 year
  • 50-100 Hz Hertz (HZ)
  • 85-260 Volt (V)
  • 111*76*48.5(L*W*H, mm) Millimeter (mm)
  • 285g (without accessory) Grams (g)
  • 1.5-3W Energy
  • Switching Signal

SDVC20- S Trade Information

  • Cheque Cash Advance (CA)
  • 1 Piece Per Week
  • 1 Week
  • 3 % Extra
  • All India
  • ISO

Product Description

FEATURES :
Automatic Voltage Regulation : Eliminate feed speed variation caused by mains voltage fluctuation.
Soft Startup : In order to avoid sudden shock to the feed material and vibratory feeder, the controller can gently increase output voltage from 0 to the preset value when startup.
Preset Speeds : 4 preset feed speeds can be stored and output by external short-circuit signal.
Remote ON/OFF Control : The controller has 2 groups of ON/OF control pins. Switch sensor ot PLC can be Connected to them to turn on/off the controller.
Photoelectric ON/OFF Control : The CUH Intelligent Photoelectric Sensor can be conrected to turn on/off the controller.
Remote Speed Control : Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 15V DC signal.
DC Control Output : The controller can output low voltage Dc power associated with logical relation setting of tne ON/OFF Control to drive a solenoid, an electrical relay or other exiernal devices.
Overheat Protection : If Internal temperature of the controller gets too high. the controller will stop its output to protect itself.
Overcurrent Protection : If output current exceeds its rated value by misoperation, the controller will stop its output to protect the controller and vibratory feeder.
Short-Circuit Protection : If output of the controller is short-circuited, the fuse inside the controller will be blown to protect the controller and vibratory feeder from further damage.

TECHNICAL SPECIFICATION

Item

Range

 

Unit

 

Description

Min

Max

Input voltage

85

260

V

AC RMS Vaule

Output voltage

0

260

V

Less than Input voltage

Output Current

0

5

A

 

Output Frequency

50/100

HZ

Mains Frequency is 50Hz

60/120

HZ

Mains Frequency is 60Hz

Output Power

0

1100

VA

 

Output Waveform

Tangent Sine

 

 

Voltage adjustmen Accuracy

1

V

 

On/OFF Delay Accuracy

0

20

s

 

ON/OFF Delay Accuracy

0.1

s

 

Soft Startup Time

0

10

s

 

DC Control output Voltage

11

13

V

DC output associated with ON/OFF control

DC Control output current

0

200

mA

Stand by Power Consumption

1.5

3

w

 

Display Method

4

Digit

LED Digital Tube

 

 

 

Control Method

1-5

V

Remote Speed

Control Voltage

Standard TTL Electric Level

 

Switching Signal

/

 

4 Buttons + LED screens

Work Space
Temperature

-10

60

°C

 

Non-Condensing

Work Space Humidity

10

85

  %

 

Enter Buying Requirement Details